Torsional mode phacoemulsification: Effective, safe cataract surgery technique of the future


1 Department of Ophthalmology, Ain-Shams University, Cairo, Egypt and Ain Shams University,Cairo, Egypt; Consultant cataract and glaucoma, Mouwasat Hospital, Kingdom of Saudi Arabia
2 Department of Ophthalmology, Ain-Shams University, Cairo, Egypt

Correspondence Address:
Ahmed M El-Moatassem Kotb
46 Ahmed Mohamed Ibrahim Street, Nasr City Area, Cairo 11471, Egypt

Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-9233.61220

Rights and Permissions

Purpose: To compare various outcome measures using torsional mode and longitudinal mode in the phacoemulsification of cataract with different nuclear densities. Setting: Magrabi Eye Hospitals, Kingdom of Saudi Arabia. Design: A randomized comparative clinical study. Materials and Methods: This study includes 200 eyes of 156 patients (100 in the ultrasound longitudinal "US" group and 100 in the torsional group). All eyes received AcrySof® single piece intraocular lens (Alcon Surgical, Fort Worth, TX). The primary outcome measures were ultrasound time (UST), cumulative dissipated energy (CDE), and surgical complications. Postoperative outcome measures were the degree of corneal edema on the first postoperative day and final best corrected visual acuity (BCVA) and CCT (central corneal thickness). Results: The differences in UST and CDE between subgroups of nucleus hardness were statistically significant (P < 0.01). The UST and CDE consistently increased in eyes with higher grades of nucleus density. On day one, the mean BCVA was 0.61 ± 0.13 decimals in the ultrasound (US) group and 0.67 ± 0.11 decimals in the torsional group (significant P < 0.05).Corneal edema was significantly less in the torsional group (P < 0.05). At 30 days, the mean BCVA was 0.94 ± 0.22 decimals in the US group and 1.0 ± 0.12 decimals in the torsional group but this difference was not statistically different (P > 0.05). Conclusions: The torsional mode provides an effective and safe method for cataract removal with lower energy usage as compared to longitudinal traditional phacoemulsification. However, the final visual outcome was similar for both study groups.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3988    
    Printed157    
    Emailed0    
    PDF Downloaded296    
    Comments [Add]    

Recommend this journal