About MEAJO | Editorial board | Search | Ahead of print | Current Issue | Archives | Instructions to authors | Online submission | Subscribe | Advertise | Contact | Login 
Middle East African Journal of Ophthalmology Middle East African Journal of Ophthalmology
Users Online: 227   Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
ORIGINAL ARTICLE
Year : 2020  |  Volume : 27  |  Issue : 1  |  Page : 10-13

Comparison of intraocular pressure changes due to exposure to mobile phone electromagnetics radiations in normal and glaucoma eye


1 Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
2 Department of Optometry, Mashhad University of Medical Sciences, Mashhad, Iran

Correspondence Address:
Dr. Farshid Karimi
Department of Optometry, Mashhad University of Medical Sciences, Mashhad
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/meajo.MEAJO_20_19

Rights and Permissions

PURPOSE: The aim of this study is to investigate the effects of electromagnetic waves (EMWs) emitted by a mobile phone on the intraocular pressure (IOP) in the eyeball. METHODS: This quasi-experimental study was conducted on 166 eyes from 83 individuals in the 40–70 age range who referred to “Khatam-al-Anbia Hospital, Mashhad, Iran” in 2016. There were two groups of participants, and the first one consisted of 41 participants who had normal eyes, whereas the second one comprised 42 participants who suffered from open-angle glaucoma disease. The IOP in both groups was measured and recorded by a specialist before and after talking 5 min on the cellphone with the help of the Goldman method. Statistical analysis such as paired t-test and analysis of variance was performed and all tests are statistically significant at (P < 0.05). For this purpose, the SPSS software (version 16) was applied. RESULTS: IOP in the glaucoma eye (42 eyes) ipsilateral to mobile phone before and after the intervention was 18.64 ± 6.7 and 23.53 ± 6.3, respectively (P < 0.001). However, IOP in the control group (41 eyes) ipsilateral to mobile phone before and after the intervention was 12.95 ± 3.5 and 13.39 ± 2.8, respectively (P = 0.063). IOP change in the opposite glaucomatous eye to mobile phone in glaucoma group (39 eyes) and normal group (44 eyes) was not significantly different before and after the phone call (P = 0.065 and P = 0.85, respectively). CONCLUSION: We found that the acute effects of EMWs emitted from the mobile phones can significantly increase the IOP in glaucoma eye, while such changes were not observed in normal eyes.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed216    
    Printed6    
    Emailed0    
    PDF Downloaded33    
    Comments [Add]    

Recommend this journal